How CQI, PMI and RI report's sends by UE towards eNodeB ?

+1 vote
1,501 views
How CQI, PMI and RI report's sends by UE towards eNodeB ?
posted May 19, 2014 by Sidharth Malhotra

Share this question
Facebook Share Button Twitter Share Button LinkedIn Share Button

1 Answer

+1 vote

The UE is requested to send either periodic or aperiodic reports concerning

Rank indication (RI)
Reports are applicable for closed- and open-loop spatial multiplexing. In case of open-loop TRI=1 corresponds to transmit diversity and TRI>1 to large delay CDD.

Precoding matrix indicator (PMI)
PMI reporting is relevant for spatial multiplexing (open- and closed-loop), MU-MIMO, closed-loop RANK=1 precoding. PMI and RI are confined to a subset of the codebook which is created by means of a codebookSubsetRestriction parameter.

Channel quality indication (CQI)
CQI may be wideband or may be related to subbands. Similar to HSPA the CQI definition is targeted at 10 % BLER whereby the overall energy per bit is nearly minimized.

enter image description here

For the purpose of periodic reporting the PUCCH is utilized, a periodic reports are sent on the PUSCH. The latter reports are explicitly requested by setting the CQI request field in connection with an uplink grant. In case of “collision” the aperiodic report will be transmitted.

Furthermore the scheduling mode can be frequency non-selective (periodic) or frequency selective (periodic and aperiodic).

The offset is signaled by nom PDSCH-RS-EPRE-Offset.

answer May 20, 2014 by Hiteshwar Thakur
Similar Questions
+3 votes

Want to know the relation between CQI and PMI/RI.

+3 votes

What if for a specific energy efficient application, I want to get rid of the periodic CQI reporting by the UE? Is it possible to do that?

+3 votes

If ENB configures some measurement event say A1,A2,A3 etc, take e.g A2 event threshhold as -100Dbm, and serving cell thrs crosses -100 then UE will send A2, after this event UE is still facing signal strength as -100dB over a long period, will UE sends second time A2 event or only once?

...