How to release Scell implicitly?

0 votes
22 views

Scell can be released either using MAC CE or RRC reconfiguration, but how to release implicitly?

posted May 19 by Poonam

Share this question
Facebook Share Button Twitter Share Button LinkedIn Share Button

2 Answers

0 votes

If PCELL initiate RRC connection reestablishment, all configured SCELL is released.

answer May 21 by Mohit Mohan
0 votes

I think query is regarding implicit scell deactivation. If UE scell is configured with sCellDeactivationTimer then on expiry of this timer (no data during this time) then UE will deactivate scell implicitly.

answer May 21 by Veer Pal Singh Yadav
Similar Questions
+2 votes

Pcell will be expecting the HARQ feedback of Scell but UE failed to decode the Scell PDCCH . This case UE doesn't send the CA HARQ and uses different PUCCH format But PCELL will be expecting different format to receive the feedback. How to overcome this issue.