Is it possible to calculate RSSI from RSRQ, RSRP, E-ARFCN

0 votes
329 views

I have the following values: 'RSRQ': -9.6875, 'RSRP': -96.0625, 'E-ARFCN': 1300
Is it possible to calculate RSSI from this? could someone provide me with formula?

posted Dec 6, 2018 by anonymous

Share this question
Facebook Share Button Twitter Share Button LinkedIn Share Button

1 Answer

0 votes

RSSI = wideband power = noise + serving cell power + interference power
Please check below calculation:
RSSI=12*N*RSRP
N=No. of Resource Blocks.
Bandwidth 1.4 MHz 3 MHz 5 MHz 10 MHz 15 MHz 20 MHz
No. of Resource Blocks (N) 6 15 25 50 75 100

answer Dec 18, 2018 by Mohit Mohan
Similar Questions
+2 votes

I was wondering if I change HO decision based on RSRP to RSRQ, do I also need to change other variables, such as a3offset, hysteresis, filter-coefficient, TTT or other variables (I don't know a lot, I am an intern). The range for RSRQ is smaller relative to RSRP. This is the reason why I am thinking that other variables need to change to adjust to the range for RSRQ.

I was looking at a dense cell site zone, where RSRQ was terrible and RSRP was very good. UE make the decisions there based on RSRP, resulting in different HO types, such as HO_Early, HO_Late, Wrong_Cell.

Did you guys come across similar problems? If so how did you guys tackle the issue?

+1 vote

What would be the difference if trigger quantity set to RSRP and report quantity set to both (RSRP and RSRQ).

Does this impact on handover failure.

+2 votes

Is there any way to get RSRP and RSRQ in an android device?

+3 votes

On what basis, source eNodeB decides to consider RSRP or RSRQ for neighbor cell power measurement ?

...