top button
Flag Notify
    Connect to us
      Site Registration

Site Registration

What will be the impact if I change parameter maxnumRRC (maximum number of RRC) in cell from 150 to 300?

0 votes
382 views

What will be the impact if I change parameter maxnumRRC (maximum number of RRC) in cell from 150 to 300, although max num of RRC in KPI reach only 73? If no impact then why we can’t set max value of maxnumRRC by default?

posted Jul 31, 2018 by anonymous

Share this question
Facebook Share Button Twitter Share Button LinkedIn Share Button

1 Answer

0 votes

To have more rrc connections at eNB, It requires more pucch resources in UL. That will reduce pusch resources so UL throughput at cell level will reduce .

answer Aug 2, 2018 by Veer Pal Singh Yadav
Similar Questions
+1 vote

Is DRX will by default present in UE?or will it be assigned by eNB?
If it is assigned by eNB,then in which message does it send to UE,in RRC setup or RRC reconfiguration or SIB2 message?

0 votes

As per my knowledge one ue will support maximum one rrc connection.

+1 vote

Which message EnodeB will communicate to MME after Receiving the Reestablishment Complete message from UE. what else messages will transverse between EnodeB and MME, before sending Reconfiguration message to UE from EnodeB after Reestablishment complete message has been received at EnodeB.

...