Does RFC4006 or 3GPP standard define any sequence while sending multiple MSCC blocks in Gy/Ro interface.

Ex: In one of the CCR-update, I am sending MSCC block having USU of previously requested units and in second MSCC block in the same CCR-update sending RSU again with different rating group.I do not see any problem in this and OCS handle this.

but when 1st MSCC block has RSU with different RG and 2nd MSCC block has USU of previously allocated units (having diff RG) SG, OCS doesn't handle this and says 5012.

In Diameter AVP sequence is not that hard and fast expect few of the avps on top.

Any thoughts?

posted Jun 19, 2017 by Bhushan Patil

Looking for an answer?  Promote on:
Facebook Share Button Twitter Share Button LinkedIn Share Button
This works fine. So answer is here:

in CCR-update(1st)
MSCC block with RSU ( RG=1)

in second CCR-update (2nd)
1st MSCC block RSU (RG=2)
2nd MSCC block USU (RG=1)

In CCA-update (2nd)
1st MSCC block : GSU for RG=2
2nd MSCC block : Result code 2001 for RG=1

Similar Questions
+3 votes

At high level, there are two type of charging mechanism. One is known as online charging and the other one is offline charging. I want to dig more in the online charging mechanism. How many types of scenarios come out in online charging ?

+2 votes

I want to understand which are the major EPC nodes involve with VoLTE Charging.

Staring from UE till IMS network.
Basically I want to know end-to-end Flow for VoLTE Charging which involves various Diameter Interface.
Does Gy interface has any role to play,if Yes,why? If No, Why?
It will be very helpful with some arrow diagrams involving the diameter interfaces without any message details.

+1 vote

Probably I know the part of the answer, still want to understand and debate the full role on Diameter Protocol in IMS. Diameter is used in all interfaces where AAA service is required in LTE may be more then 50+ interfaces are there where diameter is required. Now the question is - can we say similar thing about the IMS too or still Radius rules in IMS.

0 votes

May be the one which allows to use trial packages, also is there any application server with diameter package so to connect with HSS.

+3 votes

Hi Experts,
We are facing an issue where UE sends multiple IMS-registration requests, below is the scenario
UE is successfully registered to IMS. However UE re-sends an IMS registration request with same nonce value and receives 200 OK. Why UE re-sends IMS registration while it is already registered.