Will UE be able to quit measurement GAP if the target load balance cell doesn't meet throughput condition?

+1 vote
440 views

As per my understanding No it won’t, It will still measure the Inter frequency until the enodeb sends the interfreqency relation.

So if If it won't quit measurement gap because target cell doesn't meet throughput condition, then the UE on the source cell speeds will degrade as it stuck on measurement gap.

Should node allow UE quit to measurement gap in this scenario?

posted Jul 5, 2016 by anonymous

Share this question
Facebook Share Button Twitter Share Button LinkedIn Share Button

1 Answer

+1 vote
 
Best answer

Measurement gap configuration does not depend upon throughput condition. Suppose if multiple UEs are connected to one eNodeB and for some UEs meas gap is configured. If UE which have meas gap and is going in meas gap then this time eNodeB can schedule other UE. So that overall cell throughput will not reduce.

If eNodeB have only single ue with meas gap configured then overall throughput will be impacted. To remove the meas gap configured to UE, we need to understand the eNodeB procedure in which condition it will release the meas gap. Accordingly need to move UE in such situation to release the meas gap and then UE can get full through put.

answer Jul 21, 2016 by Veer Pal Singh Yadav
Similar Questions
+2 votes

How Paging cycle and measurement Gap is calculated?

+1 vote

how much percent of throughput affected due to measurement gap in lte

+2 votes

If rach response occurs in measurement gap can UE monitor the PDCCH?

+1 vote

If SPS PHICH occasion lies in measurement gap then How UE will handle the HARQ process?

...